Comparer nos produits

Eyestar 900 Lenstar 900
Applications
Cataract surgery
Refractive surgery
Anterior chamber analysis
IOL calculation
Premium IOL calculation
Myopia management
Biometry data
Biometry (AL, ACD, LT, CCT)
Keratometry (Dual zone anterior)
Anterior corneal topography
Posterior corneal topography
Pupillometry
White-to-white
Measurements
Technology Swept-Source-OCT OCLR
A-Scan biometry
B-Scan biometry
Measurement pattern Mandala-Scan, Virtual B-Scan, A-Scan A-Scan
Access to A-scan
Access to B-scan
Manual exclusion of outliers
Adjustment of A-scan measurement gates
Central Corneal Thickness (CCT)
Anterior Chamber Depth (ACD)
Anatomic Anterior Chamber Depth (AD)
Lens Thickness (LT)
Vitrous Chamber Depth (VCD)
Standard deviation of repeated measurements
Keratometry measurements
Technology Dual-Zone Reflective Keratometry, 32 Marker Points Dual-Zone Reflective Keratometry, 32 Marker Points
Spherical power
Astigmatism power and orientation
Flat meridian radius
Steep meridian radius
Flat meridian orientation
Steep meridian orientation
Topography measurements
Technology Swept-Source-OCT Optional Placido, 11-Ring
Anterior simulated keratometry
Posterior simulated keratometry
Anterior simulated astigmatism (power and orientation)
Posterior simulated astigmatism (power and orientation)
Axial curvature map
Tangential curvature map
Spherical elevation map
Torical elevation map
Pachymetry map
Zernike analysis / wavefront analysis
Vision simulation
Corneal maps diameter (mm / inch) up to 6mm / up to 0.24 inches
OCT imaging
Technology Swept Source OCT
Radial scans
Display of the maximal crystalline lens tilt
Display of the maximal IOL tilt
Measurement of the lens/IOL tilt
Pupillometry measurements
Technology Infra-Red Photography Infra-Red Photography
Pupil Diameter (PD)
Pupil center (barycenter)
Infra-red image
White-to-white
Technology Hi-Res Color Photography Hi-Res Color Photography
Iris diameter (ID)
Iris center (barycenter)
Color photography
Measurement process
Eye positioning Fully automatic Semi automatic or manual
Eye tracking Automatic Automatic or manual
Dense cataract mode
Measurement mode selection
"Normal" eye
Aphakic eye
Pseudophakic eye
Silicone-filled eye
Mode combination
IOL calculation
Hill-RBF Method
Hill-RBF / Abulafia Koch Toric
Barrett Universal II
Barrett True-K Toric
Barrett Toric
Haigis
Hoffer Q
Holladay 1
Olsen
SRK II and SRK/T
Masket / Modified Masket
Shammas No-History
IOL workflow
Personalization of IOL constants
IOL calculation on viewing stations
Myopia management
AMMC by Kaymak
Axial Length Growth Speed
Axial Length Normative Data
Refractive Myopia Progression Prediction
Myopia Report for Parent Education
Software modules
EyeSuite Basic
EyeSuite Biometry (Cataract Suite)
EyeSuite Anterior Chamber Suite
EyeSuite IOL Toric Planner
EyeSuite Myopia
EyeSuite Myopia AMMC
Accessoires
Instrument tables
Headrest
Chinrest
External PC (Windows only)
Networking
Electronic medical record interfaces (EyeSuite Script Language, GDT, EyeSuite Command Line Interface)
DICOM (SCU)
EyeSuite Viewing Stations
Connect to network printer
Connect to shared folder
Connect to remote database
Data import
EyeSuite Script Language Refraction Data
Dimensions
Width (cm / inch) 48 cm / 18.9 inches 31 cm / 12.2 inches
Depth (cm / inch) 56 cm / 22 inches 26 cm / 10.23 inches
Height (cm / inch ) 46 cm / 18.11 inches 42 cm / 16.53 inches
Weight (kg / pounds) 31 kg / 68.34 lbs
Electrical requirements
Line voltage 100 - 240V 100-240V
Line frequency 50 - 60Hz 50-60Hz
Power consumption 200VA
Safety certifications
Laser Class 1
● standard | ○ optional | − not available | □ not recommended

Innovateur dans le domaine de la prévision de la réfringence IOL

En collaboration avec des chirurgiens de premier plan

Haag-Streit collabore avec des chirurgiens renommés dans le monde entier depuis 2008 pour améliorer les résultats des calculs de réfringence des IOL dans divers scénarios, tels que les cas standard, les lentilles toriques et les situations post-réfractives. Cette vaste expertise a été intégrée à EyeSuite IOL, la suite logicielle de Haag-Streit pour les calculs de réfringence des IOL, et est continuellement mise à jour pour intégrer les formules les plus récentes disponibles.

Technologie de pointe

Rester à la pointe de la technologie

Depuis 2008, Haag-Streit est un pionnier dans le domaine des appareils de biométrie avec l'introduction du Lenstar 900, l'un des premiers appareils de biométrie optique. Cette technologie a révolutionné les mesures de biométrie axiale, en fournissant des résultats plus rapides et plus précis aux professionnels des soins oculaires. Nous intégrons en permanence des technologies de pointe telles que l'OCT à source balayée dans de nouveaux produits, comme l'Eyestar 900. En 2022, nous avons encore amélioré nos produits avec l'ajout de la suite pour la chambre antérieure.

Validé cliniquement

Excellents résultats chez tous les patients

Depuis son introduction en 2008, la précision de prévision du Lenstar 900 et ses excellents résultats ont été démontrés dans plus de 150* études. Vendu à des milliers d'exemplaires, le Lenstar 900 a permis à des millions de patients de bénéficier d'excellents résultats lorsqu'il a été intégré au processus de planification de leur traitement de la cataracte.

 

*Basé sur une recherche Pubmed, 5 mai 2023, mot-clé « Lenstar 900 ».