Comparar nuestros productos

Eyestar 900
Applications
Cataract surgery
Refractive surgery
Anterior chamber analysis
IOL calculation
Premium IOL calculation
Myopia management
Biometry data
Biometry (AL, ACD, LT, CCT)
Keratometry (Dual zone anterior)
Anterior corneal topography
Posterior corneal topography
Pupillometry
White-to-white
Measurements
Technology Swept-Source-OCT
A-Scan biometry
B-Scan biometry
Measurement pattern Mandala-Scan, Virtual B-Scan, A-Scan
Access to A-scan
Access to B-scan
Manual exclusion of outliers
Adjustment of A-scan measurement gates
Central corneal Thickness (CCT)
Anterior Chamber Depth (ACD)
Anatomic Anterior Chamber Depth (AD)
Lens Thickness (LT)
Vitrous Chamber Depth (VCD)
Keratometry measurements
Technology Dual-Zone Reflective Keratometry, 32 Marker Points
Spherical power
Astigmatism power and orientation
Flat meridian radius
Steep meridian radius
Flat meridian orientation
Steep meridian orientation
Topography measurements
Technology Swept-Source-OCT
Anterior simulated keratometry
Posterior simulated keratometry
Anterior simulated astigmatism (power and orientation)
Posterior simulated astigmatism (power and orientation)
Axial curvature map
Tangential curvature map
Spherical elevation map
Torical elevation map
Pachymetry map
Zernike analysis / wavefront analysis
Vision simulation
OCT imaging
Technology Swept Source OCT
Radial scans
Display of the maximal crystalline lens tilt
Display of the maximal IOL tilt
Measurement of the lens/IOL tilt
Pupillometry measurements
Technology Infra-Red Photography
Pupil Diameter (PD)
Pupil center (barycenter)
Infra-red image
White-to-white
Technology Hi-Res Color Photography
Iris diameter (ID)
Iris center (barycenter)
Color photography
Measurement process
Eye positioning Fully automatic
Eye tracking Automatic
Dense cataract mode
Measurement mode selection
"Normal" eye
Aphakic eye
Pseudophakic eye
Silicone-filled eye
Mode combination
IOL calculation
Hill-RBF Method
Hill-RBF / Abulafia Koch Toric
Barrett Universal II
Barrett True-K Toric
Barrett Toric
Haigis
Hoffer Q
Holladay 1
Olsen
SRK II and SRK/T
Masket / Modified Masket
Shammas No-History
IOL workflow
Personalization of IOL constants
IOL calculation on viewing stations
Myopia management
AMMC by Kaymak
Axial Length Growth Speed
Axial Length Normative Data
Refractive Myopia Progression Prediction
Myopia Report for Parent Education
Software modules
EyeSuite Basic
EyeSuite Biometry (Cataract Suite)
EyeSuite Anterior Chamber Suite
EyeSuite IOL Toric Planner
EyeSuite Myopia
EyeSuite Myopia AMMC
Accesorios
Instrument tables
Headrest
Chinrest
External PC (Windows only)
Networking
Electronic medical record interfaces (EyeSuite Script Language, GDT, EyeSuite Command Line Interface)
DICOM (SCU)
EyeSuite Viewing Stations
Connect to network printer
Connect to shared folder
Connect to remote database
Data import
EyeSuite Script Language Refraction Data
Dimensions
Width (cm / inch) 48 cm / 18.9 inches
Depth (cm / inch) 56 cm / 22 inches
Height (cm / inch ) 46 cm / 18.11 inches
Weight (kg / pounds) 31 kg / 68.34 lbs
Electrical requirements
Line voltage 100 - 240V
Line frequency 50 - 60Hz
Power consumption 200VA
Safety certifications
Laser Class 1
● standard | ○ optional | − not available | □ not recommended

Innovador en la predicción de potencia de la LIO

A través de la colaboración con cirujanos líderes

Haag-Streit colabora con prestigiosos cirujanos de todo el mundo desde 2008 para mejorar los resultados de los cálculos de potencia de la LIO en varios escenarios, como casos estándar, lentes tóricos y situaciones posrefractivas. Esta amplia experiencia se ha integrado en EyeSuite IOL, el paquete de software de Haag-Streit para cálculos de potencia de la LIO, y se actualiza continuamente para incorporar las fórmulas más actualizadas disponibles.

La tecnología más avanzada

Siempre a la vanguardia de la tecnología

Desde 2008, Haag-Streit ha sido pionera en dispositivos de biometría con la introducción de Lenstar 900, uno de los primeros dispositivos de biometría óptica. Esta tecnología revolucionó las mediciones de biometría axial, proporcionando resultados más rápidos y precisos para los profesionales de la visión. Integramos continuamente tecnologías de vanguardia como la OCT de espectro de barrido en nuevos productos, como Eyestar 900. En 2022, mejoramos aún más nuestros productos con la adición de Anterior Chamber Suite.