Vergleiche unsere Produkte

Eyestar 900 Lenstar 900
Applications
Cataract surgery
Refractive surgery
Anterior chamber analysis
IOL calculation
Premium IOL calculation
Myopia management
Biometry data
Biometry (AL, ACD, LT, CCT)
Keratometry (Dual zone anterior)
Anterior corneal topography
Posterior corneal topography
Pupillometry
White-to-white
Measurements
Technology Swept-Source-OCT OCLR
A-Scan biometry
B-Scan biometry
Measurement pattern Mandala-Scan, Virtual B-Scan, A-Scan A-Scan
Access to A-scan
Access to B-scan
Manual exclusion of outliers
Adjustment of A-scan measurement gates
Central Corneal Thickness (CCT)
Anterior Chamber Depth (ACD)
Anatomic Anterior Chamber Depth (AD)
Lens Thickness (LT)
Vitrous Chamber Depth (VCD)
Standard deviation of repeated measurements
Keratometry measurements
Technology Dual-Zone Reflective Keratometry, 32 Marker Points Dual-Zone Reflective Keratometry, 32 Marker Points
Spherical power
Astigmatism power and orientation
Flat meridian radius
Steep meridian radius
Flat meridian orientation
Steep meridian orientation
Topography measurements
Technology Swept-Source-OCT Optional Placido, 11-Ring
Anterior simulated keratometry
Posterior simulated keratometry
Anterior simulated astigmatism (power and orientation)
Posterior simulated astigmatism (power and orientation)
Axial curvature map
Tangential curvature map
Spherical elevation map
Torical elevation map
Pachymetry map
Zernike analysis / wavefront analysis
Vision simulation
Corneal maps diameter (mm / inch) up to 6mm / up to 0.24 inches
OCT imaging
Technology Swept Source OCT
Radial scans
Display of the maximal crystalline lens tilt
Display of the maximal IOL tilt
Measurement of the lens/IOL tilt
Pupillometry measurements
Technology Infra-Red Photography Infra-Red Photography
Pupil Diameter (PD)
Pupil center (barycenter)
Infra-red image
White-to-white
Technology Hi-Res Color Photography Hi-Res Color Photography
Iris diameter (ID)
Iris center (barycenter)
Color photography
Measurement process
Eye positioning Fully automatic Semi automatic or manual
Eye tracking Automatic Automatic or manual
Dense cataract mode
Measurement mode selection
"Normal" eye
Aphakic eye
Pseudophakic eye
Silicone-filled eye
Mode combination
IOL calculation
Hill-RBF Method
Hill-RBF / Abulafia Koch Toric
Barrett Universal II
Barrett True-K Toric
Barrett Toric
Haigis
Hoffer Q
Holladay 1
Olsen
SRK II and SRK/T
Masket / Modified Masket
Shammas No-History
IOL workflow
Personalization of IOL constants
IOL calculation on viewing stations
Myopia management
AMMC by Kaymak
Axial Length Growth Speed
Axial Length Normative Data
Refractive Myopia Progression Prediction
Myopia Report for Parent Education
Software modules
EyeSuite Basic
EyeSuite Biometry (Cataract Suite)
EyeSuite Anterior Chamber Suite
EyeSuite IOL Toric Planner
EyeSuite Myopia
EyeSuite Myopia AMMC
Accessories
Instrument tables
Headrest
Chinrest
External PC (Windows only)
Networking
Electronic medical record interfaces (EyeSuite Script Language, GDT, EyeSuite Command Line Interface)
DICOM (SCU)
EyeSuite Viewing Stations
Connect to network printer
Connect to shared folder
Connect to remote database
Data import
EyeSuite Script Language Refraction Data
Dimensions
Width (cm / inch) 48 cm / 18.9 inches 31 cm / 12.2 inches
Depth (cm / inch) 56 cm / 22 inches 26 cm / 10.23 inches
Height (cm / inch ) 46 cm / 18.11 inches 42 cm / 16.53 inches
Weight (kg / pounds) 31 kg / 68.34 lbs
Electrical requirements
Line voltage 100 - 240V 100-240V
Line frequency 50 - 60Hz 50-60Hz
Power consumption 200VA
Safety certifications
Laser Class 1
● standard | ○ optional | − not available | □ not recomended

Innovator bei der IOL-Leistungsprognose

Durch die Zusammenarbeit mit führenden Chirurgen

Haag-Streit arbeitet seit 2008 mit renommierten Chirurgen auf der ganzen Welt zusammen, um die Ergebnisse der IOL-Brechkraftberechnung in verschiedenen Szenarien, wie Standardfällen, torischen Linsen und postrefraktiven Situationen, zu verbessern. Dieses umfassende Fachwissen wurde in EyeSuite IOL, die Software-Suite von Haag-Streit für IOL-Brechkraftberechnungen, integriert und kontinuierlich aktualisiert, um die aktuellsten verfügbaren Formeln zu integrieren.

Spitzentechnologie

Technologisch führend bleiben

Seit 2008 ist Haag-Streit mit der Einführung des Lenstar 900, einem der ersten optischen Biometriegeräte, ein Pionier in der Biometrie. Diese Technologie revolutionierte die axiale Biometriemessung und liefert dem Optiker schnellere und präzisere Ergebnisse. Wir integrieren kontinuierlich modernste Technologien wie Swept-Source-OCT in neue Produkte wie den Eyestar 900. 2022 haben wir unsere Produkte mit der Anterior Chamber Suite weiter verbessert.

Klinisch validiert

Hervorragende Ergebnisse für jeden Patienten

Seit seiner Einführung im Jahr 2008 haben sich die Prognosegenauigkeit und die hervorragenden Ergebnisse des Lenstar 900 in mehr als 150* Studien bewährt. Bei Tausenden verkaufter Geräte haben Millionen von Patienten hervorragende Ergebnisse erzielt, als der Lenstar 900 Teil ihres Kataraktplanungsprozesses war.

 

*Basierend auf einer veröffentlichten Suche, 5. Mai 2023, Stichwort „Lenstar 900“