Compare nuestros productos

Lenstar Myopia
Applications
Cataract surgery ○
Refractive surgery ○
IOL calculation ○
Myopia management ●
Biometry data
Biometry (AL, ACD, LT, CCT) ●
Keratometry (Dual zone anterior) ●
Pupillometry ●
White-to-white ●
Measurements
Technology OCLR
A-Scan biometry ●
Measurement pattern A-Scan
Access to A-scan ○
Standard deviation of repeated measurements ○
Manual exclusion of outliers ○
Adjustment of A-scan measurement gates ○
Central corneal Thickness (CCT) ●
Vitrous Chamber Depth (VCD) ●
Keratometry measurements
Technology Dual-Zone Reflective Keratometry, 32 Marker Points
Spherical power ●
Astigmatism power and orientation ●
Flat meridian radius ●
Steep meridian radius ●
Flat meridian orientation ●
Steep meridian orientation ●
Topography measurements
Technology Infra-Red Photography
Pupillometry measurements
Pupil Diameter (PD) ●
Pupil center (barycenter) ●
White-to-white
Technology Hi-Res Color Photography
Iris diameter (ID) ●
Iris center (barycenter) ●
Measurement process
Eye positioning Semi automatic or manual
Eye tracking Automatic or manual
Dense cataract mode ●
Measurement mode selection ●
Myopia management
AMMC by Kaymak ●
Axial Length Growth Speed ●
Axial Length Normative Data ●
Refractive Myopia Progression Prediction ●
Myopia Report for Parent Education ●
Software modules
EyeSuite Basic ●
EyeSuite Biometry (Cataract Suite) ○
EyeSuite IOL Toric Planner ○
EyeSuite Myopia ●
EyeSuite Myopia AMMC ●
Accesorios
Instrument tables ○
Headrest ○
Chinrest ○
External PC (Windows only) ●
Networking
Electronic medical record interfaces (EyeSuite Script Language, GDT, EyeSuite Command Line Interface) ●
DICOM (SCU) ○
EyeSuite Viewing Stations ●
Connect to network printer ●
Connect to shared folder ●
Connect to remote database ●
Dimensions
Width (cm / inch) 31 cm / 12.2 inches
Depth (cm / inch) 26 cm / 10.24 inches
Height (cm / inch ) 42 cm / 16.54 inches
Weight (kg / pounds) 6.6 kg / 14.55 lbs
Electrical requirements
Line voltage 100-240V
Line frequency 50-60Hz
Power consumption 30.6 W
Safety certifications
Laser Class 1 ●
● standard | ○ optional | − not available | □ not recommended

Lenstar Myopia

Detecte, evalúe y controle la progresión de la miopía

Lenstar Myopia es una solución integral para la gestión de la miopía que combina una biometría óptica precisa con un software intuitivo para la evaluación y el seguimiento de su progresión. Al proporcionar mediciones precisas de la longitud axial y otros parámetros biométricos junto con datos refractivos, ayuda a los profesionales a identificar cambios a lo largo del tiempo, evaluar la eficacia del tratamiento e implicar a pacientes y progenitores mediante informes visuales claros e informativos.